| Related Power Dividers |
SMA-Female |
|
|
|
| |
|
|
N-Female |
|
|
|
| |
|
|
| |
7/16 DIN |
|
|
|
|
| |
|
|
| |
BNC |
|
|
|
|
|
| |
| Application Note MAP-801 |
| Why most Power Dividers are not suitable for combining. The limiting factor for most Wilkinson power dividers used as combiners is power dissipation. more... |
| |
|
|
|
| TNC Power Dividers |
Home > Power Dividers > TNC |
MECA offers TNC-Female power divider/combiners with average power ratings from 40 watts and frequency range of 0.700 - 2.700 GHz.
| Top Selling Power Divider/Combiners 1 |
Catalog
Number |
Freq.
(GHz) |
Power
(W) |
Isolation
(dB) |
Insertion
Loss (dB) |
Amplitude
Balance
(dB)
(Max) |
Phase
Balance
(degrees)
(Max) |
VSWR |
| Input |
Output |
| Typ |
Min |
Typ |
Max |
Typ |
Max |
Typ |
Max |
| 802-6-1.700V | 0.7-2.7 | 40 | 27 | 22 | 0.40 | 0.50 | 0.2 | 3 | 1.10:1 | 1.25:1 | 1.10:1 | 1.20:1 | | 803-6-1.700V | 0.7-2.7 | 40 | 27 | 22 | 0.60 | 0.80 | 0.4 | 6 | 1.25:1 | 1.45:1 | 1.10:1 | 1.20:1 | | 804-6-1.700V | 0.7-2.7 | 40 | 25 | 20 | 0.8 | 1.00 | 0.2 | 4 | 1.25:1 | 1.40:1 | 1.15:1 | 1.25:1 | | 806-6-1.700V | 0.7-2.7 | 40 | 25 | 20 | 0.8 | 1.20 | 0.4 | 8 | 1.30:1 | 1.65:1 | 1.20:1 | 1.35:1 | | 808-6-1.700V | 0.7-2.7 | 40 | 25 | 20 | 1.00 | 1.40 | 0.3 | 8 | 1.30:1 | 1.65:1 | 1.15:1 | 1.25:1 |
Request a Quote On-Line or Call 866-444-6322
Notes:
1. All units rated for maximum input power as a divider or balanced combiner with load
VSWR of 1.20:1 or better. To calculate the combining rated power the following formula is used:
(rated input power of divider * 5%) / "N" # of input channels = max input at each port for combining.
2. All output/power combiner ports are in-phase (0° difference).
3. 50 ohm nominal impedance standard.
4. Operating temperature from -55° C to +85° C.
5. N-Male and SMA-Female connectors are also available in this series.
| Theoretical power split (dB) for "n-way" power divider |
| 2-Way |
3-Way |
4-Way |
6-Way |
8-Way |
9-Way |
12-Way |
16-Way |
| 3.01 |
4.77 |
6.02 |
7.78 |
9.03 |
9.54 |
10.79 |
12.04 |
|
|
|
|
|